  Radiated Emission


PMM  PMM 9010F EMI/EMC Receiver, new "Fast" versionTop of page PMM

The new EMI Receiver PMM 9010F is based on very advanced analog to digital conversion and data processing technology that applies the FFT (Fast Fourier Transform) frequency spectrum analysis in full compliance with all the tests required by the standard CISPR 16-1-1. Same modular construction, compact size and low power consumption of the other renowned models in PMM’s Digital Receiv- ers family: PMM 9010, 9010/03P, 9010/30P.

 

Main characteristics
  • Frequency range: 10 Hz – 30 MHz, expandable to 3/6/18 GHz by the external modules 9030, 9060, 9180
  • Very low noise floor:  < -24 dBµV in band A, < -7 dBµV in band B
  • Multi-band preselector
  • All CISPR detectors, simultaneous
  • State-of-art digital technology
  • CISPR RBW filters: 200 Hz, 9 KHz (120 kHz, 1 MHz when in conjunction with the external modules)
  • 6 dB RBW filters: 1 – 3 – 10 – 30 – 100 kHz

Performances examples
  • Analyzer mode, frequency span 30 MHz
    • Real time with RBW = 300 kHz
    • With Hold time 1 s:     sweep time = 1 s  
    • With Hold time 50 ms:     sweep time = 1 s  
    • Gapless with RBW = 10 kHz & 9 kHz
    • 300 times faster than 9010 “standard”!
  • Scan/sweep mode, frequency band 9 kHz - 30 MHz
    • Scan time of less 25 second in full CISPR compliance:
      • CISPR RBW: 200 Hz, 9 KHz
      • CISPR detectors: all
      • Hold time: 1 second
      • Preselector: ON
 
Watch the video on the difference in measurement speed bettween PMM 9010F and PMM 9010

Applications:

9010F allows for exclusive advantages:
  • When measuring the conducted disturbances of such EUT not able to run all the test time long: various appliances, electric tools, toys, machinery… The 9010F avoid needing to make pre-tests and partial final tests by performing the complete test in seconds instead.
  • In test houses the 9010F cuts the conducted emission test time down nearly to zero: the set-up is available for more tests thus increasing the laboratory productivity.
  • On-site measurements of overhead lines PLT signals interference to radio communication can be done much faster – not negligible when line voltage is of half a MV or so! (RA-01HV antenna recommended)

Product description and specifications PDF format : English


PMM  9010/30PTop of page PMM
 

PMM 9010/30P EMI Measuring Receiver & Analyzer 10 Hz - 3 GHz.


 PMM 9010/30P NARDA-PMM innovative concept in EMC Testing has generated a new EMC/EMI Receiver with a revolutionary approach to the most felt requirements by medium and small size laboratories which don’t feel very comfortable investing in a CISPR 16-1-1 Full-Compliant Receiver for Radiated Frequency Range too.
In practice, to perform truly Full Compliant Radiated Emission Tests, an appropriate test site should be made available for hosting both EUT (Equipment Under Test) and Receiving Antenna separated by 3, 10 or even 30 meters distance, like SAC (Semi-Anechoic Chambers) or OATS (Open Area Test Sites), this usually means an huge investment in terms of RF shielding and absorbing materials.
Nevertheless, with appropriate methodology and care to discriminate as much as possible noise contributions coming from the environment vs. those generated by the EUT, it’s also possible to perform good evaluative radiated emission tests in an Open Space with a Pre-Compliant Receiver and this is exactly the purpose 9010/30P has been designed for in the range 30 - 3000 MHz. On the other side, looking to Conducted Emissions Tests requirements, Full Compliance toward each specific Product Standard can be easily fulfilled with a significantly lower budget investment, i.e. no specific environment is required but only few components (EMI Receiver, LISN or High Voltage Probe, etc.), and that’s why having a Full Compliant Receiver for the range 9 kHz - 30 MHz becomes really convenient just comparing its cost to that of tests performed in a 3rd party laboratory.
In few words, with PMM 9010/30P the mix of Full and Pre-Compliant features provides a perfect match to practical testing requirements, not excluding the possibility of future upgrades to 100% CISPR 16-1-1 Full-Compliance up to 3 or 6 GHz or 18 GHz with simple addition of PMM 9030 or PMM 9060 or PMM 9180 extension units digitally connected through fiber optic cable. All other features provided by previously released PMM 9010 Full-Compliant Receiver remains unchanged in 9010/30P too, including optional Click Analyzer Function and MIL-STD 461 Filters.
The already widely appreciated software “PMM Emission Suite” can properly control 9010/30P as well.

 Product description and specifications PDF formatEnglish


PMM  9010Top of page PMM
 PMM 9010

PMM 9010 EMC/EMI Receiver 10Hz - 30 MHz.

Save your time and money with our Fully Digital fully CISPR Compliant EMI Receiver and Analyzer.
Combined with the PMM 9030 the receiver extends its range from 10Hz to 3 GHz, or with the PMM 9060 it extends its range from 10Hz to 6 GHz and with the PMM 9180 it extends its range up to 18 GHz.

Read more details...>

Product description PDF formatEnglish


 PMM  9180Top of page PMM
     
  PMM 9180  

PMM 9180 EMC/EMI Receiver 6 GHz - 18 GHz.

PMM 9180 is the frequency extension unit that brings the popular, outstanding full-compliant EMI Receiver PMM 9010 up to the 18 GHz frequency for radiated emission tests. Thanks to its small size, battery power and high-speed optical link the PMM 9180 can be installed directly on the antenna connector thus dramatically reducing the measurement uncertainties due to coax cables and connectors. Full compliance to CISPR 16-1-1 and latest addenda.

Read more details...>

Product description PDF formatEnglish


 PMM 9060Top of page PMM
  PMM 9060  

PMM 9060 EMC/EMI Receiver 30 MHz - 6 GHz.

PMM 9060 is the frequency extension unit that brings the popular, outstanding full-compliant EMI Receiver PMM 9010 up to the 6 GHz frequency for radiated emission tests. Thanks to its small size, battery power and high-speed optical link the PMM 9060 can be installed directly on the antenna connector thus dramatically reducing the measurement uncertainties due to coax cables and connectors. Full compliance to CISPR 16-1-1 and latest addenda.

Read more details...>

Product description PDF formatEnglish


 PMM 9030Top of page PMM
  PMM 9030  

PMM 9030 EMC/EMI Receiver 30 MHz - 3 GHz.

We are pleased to announce the new DIGITAL EMC/EMI RECEIVER fully CISPR compliant, in the 30 MHz - 3 GHz range, that extends the PMM 9010 up to the field of radiated emissions frequency range. A fast and safe connection with PMM 9010 is guaranteed by a high speed optical link, providing a complete immunity of transferred data.

Read more details...>

Product description PDF formatEnglish


PMM  PMM Emission Suite SoftwareTop of page PMM
 PMM 9010

PMM 9010/9030/9060 Emission Suite PC Software.

A powerful Software Utility that add PMM 9010, PMM 9030 and PMM 9060 receivers of extremely useful functions to control measurements as well as to collect, analyze and post-process data safely and easily as never before.
 

Read more details...>

Product description PDF format : English


PMM  7010 All-in-one EMI ReceiverTop of pagePMM

The new EMI Receiver PMM 7010 matches the legendary operability of all PMM receivers with the most advanced digital technology and with the completeness of the software PMM Emission Suite.
Specifically designed for reliable EMC pre-testing and debugging, the PMM 7010 helps reducing the time-to-market of new products. 

Product description PDF formatEnglish

PMM 7010


 PMM AS-02Top of page PMM
   

AS-02 Antenna Set 30 MHz - 3 GHz

MAIN FEATURES

  • 30 MHz to 3 GHz frequency range
  • Excellent Antenna Factor
  • Tripod adapter for easy vertical-horizontal polarization change
  • Individual calibration
  • Robust, rustproof construction
  • Lightweight

PMM AS-02 is a compact size broadband Antenna System composed of a PMM BC-01 Biconical Dipole and PMM LP-02 Log Periodic Dipole Array designed for application in radiated emissions and immunity.
It can be used in conjuntion with any receiver or spectrum analyzer.
Its ideal companion is the EMI Receiver Unit PMM9030 that can be easily mounted on the antenna mast.

Product description PDF format : Italiano
 


 PMM AS-03Top of page PMM
   

AS-03 Antenna Set 30 MHz - 6 GHz

MAIN FEATURES

  • 30 MHz to 6 GHz frequency range
  • Excellent Antenna Factor
  • Tripod adapter for easy vertical-horizontal polarization change
  • Individual calibration
  • Robust, rustproof construction
  • Lightweight

PMM AS-03 is a compact size broadband Antenna System composed of a PMM BC-01 Biconical Dipole, PMM LP-02 and PMM LP-03 Log Periodic Dipole Array designed for application in radiated emissions and immunity .
It can be used in conjuntion with any receiver or spectrum analyzer.
Its ideal companion is the EMI Receiver Unit PMM9060 that can be easily mounted on the antenna mast

Product description PDF format : Italiano
 


 PMM DR-01Top of page PMM
   

DR-01 Double-ridged horn antenna 6-18 GHz

MAIN FEATURES

  • 6 to 18 GHz frequency range
  • Excellent Antenna Factor and VSWR
  • Tripod adapter for easy vertical-horizontal polarization change
  • Individual calibration
  • Robust, rustproof construction
  • Lightweight

DR-01 is a broadband, double-ridged horn antenna designed for radiated emissions and immunity applications.The N connector is mounted along the antenna axis, thus allowing for direct con-nection - without cable or adapters - to the 18 GHz EMI receiver model 9180 which features full CISPR 16-1-1 compliance and internal preamplifier. .The group antenna-receiver can be easily installed on a tripod or mast and con-nected by means of fiber optic cable to the main unit model PMM 9010 - 9010F, thus increasing sensitivity and reducing overall uncertainty. DR01 can be used in conjunction with any Receiver or Spectrum Analyzer.

Product description PDF format : Italiano
 


 PMM LP-02Top of page PMM
   

LP-02 Log Periodic Antenna 0,2 - 3 GHz

MAIN FEATURES
• 200 MHz to 3 GHz frequency range
• Excellent Antenna factor
• Tripod adapter for easy vertical - horizontal polarization change
• Individual calibration
• Robust, rustproof aluminium construction
• Lightweight
PMM LP-02 is a log-periodic antenna designed for application in radiated EMC.
It can be used in conjunction with any Receiver or Spectrum Analyzer.
Its ideal companion is the EMI Receiver Unit PMM 9030 that can be easily
mounted on the antenna mast (*).
PMM LP-02 is also available in a convenient Antenna Sets
AS-02 (30 MHz - 3 GHz) including the Antenna models BC-01 & LP-02.
AS-03 (30 MHz - 6 GHz) including the Antenna models BC-01,LP-02 & LP-03.

Product description PDF formatEnglish

 PMM LP-03Top of page PMM
   

LP-03 Log Periodic Antenna 0,8 - 6 GHz

MAIN FEATURES
• 0,8 to 6 GHz frequency range
• Excellent flatness
• Tripod mounting
• Individual calibration
• Robust, rustproof aluminium construction
• Lightweight
PMM LP-03 is a log-periodic antenna designed for application in radiated EMC.
It can be used in conjunction with any Receiver or Spectrum Analyzer.
Its ideal companion is the EMI Receiver Unit PMM 9060 that can be easily
mounted on the antenna mast (*).
PMM LP-03 is also available in a convenient Antenna Kit AS-03 inclusive of the
antennas mod. BC-01 & LP-02 to cover the 30 MHz — 6 GHz frequency range.
(*)The direct connection between antenna and Receiver Unit PMM 9060 eliminates
additional sources of uncertainties due to coaxial cable attenuation and scattering.

Product description PDF formatEnglish


 PMM BC-01Top of page PMM
   

BC-01 Biconical Antenna 30 - 200 MHz

MAIN FEATURES
• 30 to 200 MHz frequency range
• Excellent Antenna Factor
• Tripod adapter for easy vertical - horizontal polarization change
• Individual calibration
• Robust, rustproof aluminium construction
• Lightweight
PMM BC-01 is a biconical antenna designed for application in radiated EMC.
It can be used in conjunction with any Receiver or Spectrum Analyzer.
Its ideal companion is the EMI Receiver Unit PMM 9030 that can be easily
mounted on the antenna mast (*).
Also available in portable,convenient Antenna Sets
AS-02 (30 MHz - 3 GHz) including the Antenna models BC-01 & LP-02.
AS-03 (30 MHz - 6 GHz) including the Antenna models BC-01, LP-02 & LP-03.

Product description PDF formatEnglish


 PMM RA-01Top of page PMM
 PMM RA-01  

RA-01 Low frequency rod antenna

PMM RA01 is perfect for RF field measurements in a wide variety of EMC applications,
including interference measurements from high-voltage power lines.
PMM RA01 can be used in conjunction with any Receiver or Spectrum Analyzer,although
its ideal companion for on site measurements is the Digital EMI Receiver PMM 9010,
portable and fully compliant to CISPR-16-1-1.

Main features

  • 9 kHz to 30 MHz (RA01);
  • 150 kHz to 30 MHz (RA01HV) frequency range
  • Built-in preamplifier for high sensitivity
  • Rechargeable battery of long operation time
  • Excellent flatness
  • Tripod mounting adapter
  • Individual calibration
  • Easy assembling
  • High rejection to mains frequencies
  • Robust,rustproof aluminium case,ground plane and rod

Product description PDF formatEnglish



 PMM RF-300Top of page PMM
 PMM RF-300  

Large Loop Antenna System (LLAS)

PMM RF-300 Large Loop Antenna System (LLAS) for EN 55015 (CISPR-15) Emission Testing of Luminaires.

Main features
• Fully compliant with EN 55015 (CISPR-15)
• 9 kHz to 30 MHz calibrated frequency range
• Complete 3 axis system with switching unit
• 2 meter diameter loops
• Simple to install, store and transport
• Can be used with any EMI receiver
• Ideal companion of PMM 9010 Digital EMI receiver (CISPR-16-1-1 full compliant)


Product description PDF formatEnglish



 PMM VDH-01Top of page PMM
 PMM VDH-01  

PMM VDH-01 Van der Hoofden test-head (IEC 62493)

PMM VDH-01 is a Van der Hoofden test-head designed to meet the specification of the IEC 62493 standard for
the EMF assessment of lighting products in relation to human exposure, requiring the measurements of in-
duced currents in the frequency range 20 kHz - 10 MHz.

  • Physical dimensions and electrical characteristics according to IEC 62493
  • Protection network included
  • Individual calibration
  • Robust, rustproof construction
  • Lightweight Automatic calculation of factor F (in conjunction with PMM Emission Suite and PMM 9010 EMI receiver)

The test-head is composed by a conductive sphere of 210 mm diameter simulating the human head, by a connecting wire simulating the neck and by a passive network that matches the EMI receiver 50 Ohm input impedance and prevents it from overloading.
The PMM VDH-01 can be used with any CISPR-compliant EMI receiver; when used in conjunction with the EMI receiver PMM 9010, the measurement settings and the computing functions are automatically performed by
the PMM Emission Suite software.


Product description PDF formatEnglish


 PMM AntennasTop of pagePMM
 Antennas  

Antennas

A wide range of antenna systems is available. Each antenna is individually calibrated. Until 50 MHz the monopole antenna (active and passive rod) are calibrated with the substitution method.
The loop antennas are calibrated inside an anechoic chamber by measuring the current in a primary loop and calculating the induction field. The loop to be calibrated is placed in this known field and the antenna factor is measured.

 

 


PMM  AccessoriesTop of pagePMM
Clamp SHC1
PL01

Accessories

A wide range of accessories such as: Antennas, High Voltage Probes, Absorbing Clamps, Near Field Probes, Preamplifier, etc. complete the range of products. This provides the operator for the correct set-up for any EMC standard. 

AS-02

 

Company Worldwide
 Click here to see Authorized Dealers Worldwide
Company in Italy
 Click here to see Dealers and Companies represented in Italy
Product Catalog
Download the Product Catalog Short-Form Catalog
Online RMA
Check your RMA Status RMA Request
RMA Status
Join Mailing List
  email Address:
  Name:



Valid XHTML 1.0 Transitional CSS Valid!       Top of Page    Copyright © Narda Safety Test Solutions S.r.l. MCMXCVIII-MMXIV. All rights reserved. PIVA 00972040091 http://www.livio.net/